[Delay time until 1394 transaction start]
Default value is 4.You can set delay time for some SCSI devices which will
not receive any command if a next command is issued right after Start/Stop
Unit command is issued.
[Enable SCSI bus reset]
Default value is enabled.You can set whether the FR1SX issues SCSI bus
reset to a SCSI device or not.
[Enable START UNIT command]
Default value is disabled. You have to enable START UNIT command for
some SCSI devices which will not work if they does not receive this START
UNIT command.
[Enable parity check]
Default value is enabled. You can set parity check enable or disable.
[Target SCSI ID.]
Default value is AUTO. You can set target SCSI ID No.
[Max Payload Size]
Default value is 1024. You can set Max byte size in
transferring IEEE1394 Read/Write DataBlock. Max size is 2048 Bytes. But,
if a data error happens during data transfer, you should set this value to 1024
Bytes to avoid the error.